精品一区二区三区免费视频,美女做爰a片毛片aaaa,日本熟妇毛茸茸,久久精品国产亚洲av四区

您好!歡迎訪問上海根生生物科技有限公司網(wǎng)站!
全國服務(wù)咨詢熱線:

15216781845

當(dāng)前位置:首頁 > 產(chǎn)品中心 > > 其它耗材與試劑 > BD556547BD細胞凋亡試劑盒FITC Annexin V Apoptosis Detection Kit I

BD細胞凋亡試劑盒FITC Annexin V Apoptosis Detection Kit I

簡要描述:ContentsAnnexin V-FITC, Propidium Iodide Staining Solution, Annexin V Binding BufferSize100 TestsRegulatory Status RUO
*,*,*,咨詢

  • 產(chǎn)品型號:BD556547
  • 廠商性質(zhì):代理商
  • 更新時間:2024-04-16
  • 訪  問  量:14046

詳細介紹

 Description

Apoptosis is a normal physiologic process which occurs during embryonic development as well as in maintenence of tissue homeostasis. The

apoptotic program is characterized by certain morphologic features, including loss of plasma membrane asymmetry and attachment,

condensation of the cytoplasm and nucleus, and internucleosomal cleavage of DNA. Loss of plasma membrane is one of the earliest features.

In apoptotic cells, the membrane phospholipid phosphatidylserine (PS) is translocated from the inner to the outer leaflet of the plasma

membrane, thereby exposing PS to the external cellular environment. Annexin V is a 35-36 kDa Ca2+ dependent phospholipid-binding

protein that has a high affinity for PS, and binds to cells with exposed PS. Annexin V may be conjugated to fluorochromes including FITC.

This format retains its high affinity for PS and thus serves as a sensitive probe for flow cytometric analysis of cells that are undergoing

apoptosis. Since externalization of PS occurs in the earlier stages of apoptosis, FITC Annexin V staining can identify apoptosis at an earlier

stage than assays based on nuclear changes such as DNA fragmentation.

FITC Annexin V staining precedes the loss of membrane integrity which accompanies the latest stages of cell death resulting from either

apoptotic or necrotic processes. Therefore, staining with FITC Annexin V is typically used in conjunction with a vital dye such as propidium

iodide (PI) or 7-Amino-Actinomycin (7-AAD) to allow the investigator to identify early apoptotic cells (PI negative, FITC Annexin V

positive). Viable cells with intact membranes exclude PI, wheras the membranes of dead and damaged cells are permeable to PI. For example,

cells that are considered viable are FITC Annexin V and PI negative; cells that are in early apoptosis are FITC Annexin V positive and PI

negative; and cells that are in late apoptosis or already dead are are both FITC Annexin V and PI positive. This assay does not distinguish

between cells that have undergone apoptotic death versus those that have died as a result of a necrotic pathway because in either case, the dead

cells will stain with both FITC Annexin V and PI. However, when apoptosis is measured over time, cells can be often tracked from FITC

Annexin V and PI negative (viable, or no measurable apoptosis), to FITC Annexin V positive and PI negative (early apoptosis, membrane

integrity is present) and finally to FITC Annexin V and PI positive (end stage apoptosis and death). The movement of cells through these three

stages suggests apoptosis. In contrast, a single observation indicating that cells are both FITC Annexin V and PI positive, in of itself, reveals

less information about the process by which the cells underwent their demise.

Preparation and Storage

Store undiluted at 4°C and protected from prolonged exposure to light. Do not freeze.

556547 Rev. 5 Page 1 of 3

Flow Cytometric Analysis of FITC Annexin V staining. Jurkat cells

(Human T-cell leukemia; ATCC TIB-152) were left untreated (top

panels) or treated for 4 hours with 12 μM campotothecin (bottom

panels). Cells were incubated with FITC Annexin V in a buffer

containing propidium iodide (PI) and analyzed by flow cytometry.

Untreated cells were primarily FITC Annexin V and PI negative,

indicating that they were viable and not undergoing apoptosis. After a

4 hour treatment (bottom panels), there were primarily two

populations of cells: Cells that were viable and not undergoing

apoptosis (FITC Annexin V and PI negative) and cells undergoing

apoptosis (FITC Annexin V positive and PI negative). A minor

population of cells were observed to be FITC Annexin V and PI

positive, indicating that they were in end stage apoptosis or already

dead.

Application Notes

Application

Flow cytometry Routinely Tested

Recommended Assay Procedure:

FITC Annexin V is a sensitive probe for identifying apoptotic cells, binding to negatively charged phospholipid surfaces (Kd of ~5 x 10^-2) with

a higher affinity for phosphatidylserine (PS) than most other phospholipids. FITC Annexin V binding is calcium dependent and defined calcium

and salt concentrations are required for optimal staining as described in the FITC Annexin V Staining Protocol. Investigators should note that

FITC Annexin V flow cytometric analysis on adherent cell types (e.g HeLa, NIH 3T3, etc.) is not routinely tested as specific membrane

damage may occur during cell detachment or harvesting. Methods for utilizing Annexin V for flow cytometry on adherent cell types,

however, have been previously reported (Casiola-Rosen et al. and van Engelend et al.).

INDUCTION OF APOPTOSIS BY CAMPTOTHECIN

The following protocol is provided as an illustration on how FITC Annexin V may be used on a cell line (Jurkat).

Materials

1. Prepare Camptothecin stock solution (Sigma-Aldrich Cat. No. C-9911): 1 mM in DMSO.

2. Jurkat T cells (ATCC TIB-152).

Procedure

1. Add Camptothecin (final conc. 4-6 μM) to 1 x 10^6 Jurkat cells.

2. Incubate the cells for 4-6 hr at 37°C.

3. Proceed with the FITC Annexin V Staining Protocol to measure apoptosis.

FITC ANNEXIN V STAINING PROTOCOL

FITC Annexin V is used to quantitatively determine the percentage of cells within a population that are actively undergoing apoptosis. It relies on

the property of cells to lose membrane asymmetry in the early phases of apoptosis. In apoptotic cells, the membrane phospholipid

phosphatidylserine (PS) is translocated from the inner leaflet of the plasma membrane to the outer leaflet, thereby exposing PS to the external

environment. Annexin V is a calcium-dependent phospholipid-binding protein that has a high affinity for PS, and is useful for identifying

apoptotic cells with exposed PS. Propidium Iodide (PI) is a standard flow cytometric viability probe and is used to distinguish viable from

nonviable cells. Viable cells with intact membranes exclude PI, whereas the membranes of dead and damaged cells are permeable to PI. Cells that

stain positive for FITC Annexin V and negative for PI are undergoing apoptosis. Cells that stain positive for both FITC Annexin V and PI are

either in the end stage of apoptosis, are undergoing necrosis, or are already dead. Cells that stain negative for both FITC Annexin V and PI are

alive and not undergoing measurable apoptosis.

556547 Rev. 5 Page 2 of 3

Reagents

1. FITC Annexin V (component no. 51-65874X): Use 5 μl per test.

2. Propidium Iodide (PI) (component no. 51-66211E) is a convenient, ready-to-use nucleic acid dye. Use 5 μl per test.

3. 10X Annexin V Binding Buffer (component no. 51-66121E): 0.1 M Hepes/NaOH (pH 7.4), 1.4 M NaCl, 25 mM CaCl2. For a 1X working

solution, dilute 1 part of the 10X Annexin V Binding Buffer to 9 parts of distilled water.

Staining

1. Wash cells twice with cold PBS and then resuspend cells in 1X Binding Buffer at a concentration of 1 x 10^6 cells/ml.

2. Transfer 100 μl of the solution (1 x 10^5 cells) to a 5 ml culture tube.

3. Add 5 μl of FITC Annexin V and 5 μl PI.

4. Gently vortex the cells and incubate for 15 min at RT (25°C) in the dark.

5. Add 400 μl of 1X Binding Buffer to each tube. Analyze by flow cytometry within 1 hr.

SUGGESTED CONTROLS FOR SETTING UP FLOW CYTOMETRY

The following controls are used to set up compensation and quadrants:

1. Unstained cells.

2. Cells stained with FITC Annexin V (no PI).

3. Cells stained with PI (no FITC Annexin V).

Other Staining Controls:

A cell line that can be easily induced to undergo apoptosis should be used to obtain positive control staining with FITC Annexin V and/or FITC

Annexin V and PI. It is important to note that the basal level of apoptosis and necrosis varies considerably within a population. Thus, even in the

absence of induced apoptosis, most cell populations will contain a minor percentage of cells that are positive for apoptosis (FITC Annexin V

positive, PI negative or FITC Annexin V positive, PI positive).

The untreated population is used to define the basal level of apoptotic and dead cells. The percentage of cells that have been induced to undergo

apoptosis is then determined by subtracting the percentage of apoptotic cells in the untreated population from percentage of apoptotic cells in the

treated population. Since cell death is the eventual outcome of cells undergoing apoptosis, cells in the late stages of apoptosis will have a damaged

membrane and stain positive for PI as well as for FITC Annexin V. Thus the assay does not distinguish between cells that have already undergone

an apoptotic cell death and those that have died as a result of necrotic pathway, because in either case the dead cells will stain with both FITC

Annexin V and PI.

Product Notices

1. Since applications vary, each investigator should titrate the reagent to obtain optimal results.

2. Source of all serum proteins is from USDA inspected abattoirs located in the United States.

Caution: Sodium azide yields highly toxic hydrazoic acid under acidic conditions. Dilute azide compounds in running water before

discarding to avoid accumulation of potentially explosive deposits in plumbing.

3.

4. Please refer to www.bdbiosciences.com/pharmingen/protocols for technical protocols.

References

Andree HA, Reuingsperger CP, Hauptmann R, Hemker HC, Hermens WT, Willems GM. Binding of vascular anticoagulant alpha (VAC alpha) to planar

phospholipid bilayers. J Biol Chem. 1990; 265(9):4923-4928. (Biology)

Casciola-Rosen L, Rosen A, Petri M, Schlissel M. Surface blebs on apoptotic cells are sites of enhanced procoagulant activity: implications for coagulation events

and antigenic spread in systemic lupus erythematosus. Proc Natl Acad Sci U S A. 1996; 93(4):1624-1629. (Biology)

Homburg CH, de Haas M, von dem Borne AE, Verhoeven AJ, Reuingsperger CP, Roos D. Human neutrophils lose their surface Fc gamma RIII and acquire

Annexin V binding sites during apoptosis in vitro. Blood. 1995; 85(2):532-540. (Biology)

Koopman G, Reuingsperger CP, Kuijten GA, Keehnen RM, Pals ST, van Oers MH. Annexin V for flow cytometric detection of phosphatidylserine expression on

B cells undergoing apoptosis. Blood. 1994; 84(5):1415-1420. (Biology)

Martin SJ, Reuingsperger CP, McGahon AJ, et al. Early redistribution of plasma membrane phosphatidylserine is a general feature of apoptosis regardless of

the initiating stimulus: inhibition by overexpression of Bcl-2 and Abl. J Exp Med. 1995; 182(5):1545-1556. (Biology)

O'Brien MC, Bolton WE. Comparison of cell viability probes compatible with fixation and permeabilization for combined surface and intracellular staining in flow

cytometry. Cytometry. 1995; 19(3):243-255. (Biology)

Raynal P, Pollard HB. Annexins: the problem of assessing the biological role for a gene family of multifunctional calcium- and phospholipid-binding proteins.

Biochim Biophys Acta. 1994; 1197(1):63-93. (Biology)

Schmid I, Krall WJ, Uittenbogaart CH, Braun J, Giorgi JV. Dead cell discrimination with 7-amino-actinomycin D in combination with dual color immunofluorescence

in single laser flow cytometry. Cytometry. 1992; 13(2):204-208. (Biology)

van Engeland M, Ramaekers FC, Schutte B, Reuingsperger CP. A novel assay to measure loss of plasma membrane asymmetry during apoptosis of adherent

cells in culture. Cytometry. 1996; 24(2):131-139. (Biology)

Vermes I, Haanen C, Steffens-Nakken H, Reuingsperger C. A novel assay for apoptosis. Flow cytometric detection of phosphatidylserine expression on early

apoptotic cells using fluorescein labelled Annexin V. J Immunol Methods. 1995; 184(1):39-51. (Biology)

556547

 

產(chǎn)品咨詢

留言框

  • 產(chǎn)品:

  • 您的單位:

  • 您的姓名:

  • 聯(lián)系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結(jié)果(填寫阿拉伯?dāng)?shù)字),如:三加四=7
上海根生生物科技有限公司
地址:上海市奉賢區(qū)南橋鎮(zhèn)南橋路377號1幢
郵箱:genshengtech@163.com
傳真:86-021-64190979
關(guān)注我們
歡迎您關(guān)注我們的微信公眾號了解更多信息:
歡迎您關(guān)注我們的微信公眾號
了解更多信息
国产精品99久久久久久| 丝袜灬啊灬快灬高潮了AV| 免费高清理伦片a片在线观看| 挺进大幂幂的滋润花苞御女天下 | 最近免费韩国电影高清版无吗 | 名门嫡姝-213大h慎入| 思思久久精品在热线热| 再深点灬舒服灬太大了| 人妻を催眠えっちに孕ませるまで| 40厘米黑人与中国女人| 图片区小说区另类春色首页| 男人猛躁进女人的毛片a片| 久久久受www免费人成| 寡妇好丰满奶好大有声小说| 学生挺进老师的小窄肉里| 亚洲 小说区 图片区 都市| 娇小的学生videos16hd| 国产男女无遮挡猛进猛出| 亚洲熟妇少妇任你躁在线观看无码| 又黄又爽的无遮挡免费视频人妖 | 全文辣肉h短篇春野小农民| 擦老太bbb擦bbb擦bbb擦| 日产无人区一线二线三线| 永久免费的啪啪网站免费观看浪潮| 岳肥肉紧嫩嫩伦69| 把你cao烂好不好高h| 邻居少妇张开双腿让我爽一夜| 雯雯被四个男人拖进工地| 成人妇女免费播放久久久| 女人高潮时一吸一夹| 暴虐sm调教a片| ysl千人千色yese88网站| 《善良的小峓子在钱完整版韩剧》 | 少妇人妻人伦a片| 无码一区二区三区在线观看| 亚洲一区二区三区高清在线观看| 久久精品国产亚洲av香蕉高清| 国内熟女精品熟女a片视频小说 | 爆乳上司julia中文字幕| 黑人勃起太大进不去| 国语我和子的乱视频|